Milwaukee MW14 Digital Iron Tester
The Milwaukee MW14 High Range Iron Photometer lets you go digital with your testing. No more hit and miss testing with strips.
DESCRIPTION
The Milwaukee MW14 High Range Iron Photometer lets you go digital with your testing. No more hit and miss testing with strips. Great for aquariums, Aquaculture & Coral, labs, water conditioning, classroom and more. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.
Simply add the reagent and get a digital reading accurate to ±0.04 ppm +/- 2% of reading @ 25°C within minutes.
DESIGN FEATURES
- Fast, easy-to-read results with large digital LCD readout.
- Range from 0.0 to 5.00 ppm.
- Accurate to ±0.04 ppm or ±2% of reading @ 25 °C.
- Small and ergonomic design.
- No calibration needed.
- Reliable and repeatable measurements with no visual assessment.
- Adaptation of the USEPA Method Phenatroline 315B. The reaction between Iron and the reagent causes an orange tint in the sample.
- Runs on 1 x AAA battery with auto shut off to extend battery life.
SPECIFICATIONS
- Range: 0.00 to 5.00 ppm
- Resolution: 0.01 ppm
- Accuracy: ±0.04 ppm or ±2% of reading @ 25 °C
- Typical EMC Dev: ±0.01 ppm
- Light Source: Light Emitting Diode @ 525 nm
- Light Detector: Silicon Photocell
- Method: Adaptation of USEPA Phenatroline Method 315B - The reaction between Iron and the reagent causes an orange tint in the sample.
- Environment: 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
- Battery Type: 1 x 1.5V AAA
- Auto-shut off: After 2 minutes of non-use
- Meter Dimensions: 3.2 x 2.4 x 1.5 inches (81.30 x 61 x 38.1 mm)
- Meter Weight: 0.14 lbs. (0.18 kg)
- Packaged Dimensions: 4.53 x 4.53 x 3.31 inches (115 x 115 x 84 mm)
- Packaged Weight: 0.4 lbs, (0.18 kg)
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent